Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.uci.cu/jspui/handle/123456789/10904
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMéndez Mederos, Arianne-
dc.contributor.advisorZamora Abrahante, Ianko-
dc.contributor.authorRomero Petrova, Javier Alejandro-
dc.coverage.spatial1001206en_US
dc.date.accessioned2025-11-10T15:50:01Z-
dc.date.available2025-11-10T15:50:01Z-
dc.date.issued2024-12-
dc.identifier.urihttps://repositorio.uci.cu/jspui/handle/123456789/10904-
dc.description.abstractXAVIA PACSViewer es un sistema desarrollado por el Centro de Informática Médica (CESIM) para la visualización y procesamiento de imágenes médicas digitales. Además, cumple con los estándares internacionales DICOM para la gestión de imágenes médicas y sus informes de diagnóstico. En ocasiones, cuando el especialista realiza mediciones, estas se salen del plano de visualización de la imagen, lo que dificulta el cálculo de ángulos con las herramientas actuales del sistema. En ausencia de estas herramientas, el especialista debe recurrir a mediciones manuales en placas impresas, lo que puede afectar la precisión del diagnóstico. Ahora se va a desarrollar una nueva funcionalidad: el módulo de Ortopedia que se integrará al sistema XAVIA PACSViewer. Dentro de la Ortopedia, que es una rama de la medicina, se diagnostican varias enfermedades como la escoliosis, que se diagnostica a través del método de Cobb, y también existe una condición biomecánica llamada Balance Sagital, que se diagnostica a través de los parámetros espino pélvicos. El objetivo de la investigación es desarrollar una funcionalidad para el cálculo de la amplitud angular para el diagnóstico de la escoliosis y el balance sagital en el sistema XAVIA PACSViewer que permita medir correctamente y de manera cómoda, mejorando así la precisión diagnóstica. Para ello, se emplearon métodos teóricos, métodos empíricos y técnicas de investigación. Las herramientas utilizadas en el desarrollo incluyen el lenguaje C#, .NET Framework, el entorno de desarrollo integrado Visual Studio 2022 y Visual Paradigm como herramienta CASE. El aporte práctico de esta aplicación es la capacidad de realizar mediciones angulares precisas y eficientes, lo que asegura diagnósticos más exactos y confiables, beneficiando tanto a los especialistas como a los pacientes en el ámbito ortopédico.en_US
dc.description.abstractXAVIA PACSViewer is a system developed by the Center for Medical Informatics (CESIM) for the visualization and processing of digital medical images. In addition, it complies with international DICOM standards for the management of medical images and their diagnostic reports. Sometimes, when the specialist takes measurements, these go out of the image visualization plane, making it di cult to calculate angles with the system’s current tools. In the absence of these tools, the specialist must resort to manual measurements on printed plates, which can a ect the accuracy of the diagnosis. A new functionality is now being developed: the Orthopedics module that will be integrated into the XAVIA PACSViewer system. Within Orthopedics, which is a branch of medicine, several diseases are diagnosed, such as scoliosis, which is diagnosed using the Cobb method, and there is also a biomechanical condition called Sagittal Balance, which is diagnosed through spinopelvic parameters. The objective of the research is to develop a functionality for calculating the angular amplitude for the diagnosis of scoliosis and sagittal balance in the XAVIA PACSViewer system that allows correct and comfortable measurement, thus improving diagnostic accuracy. Theoretical methods, empirical methods, and research techniques were used for this. The tools used in the development include the C# language, .NET Framework, the integrated development environment Visual Studio 2022, and Visual Paradigm as a CASE tool. The practical contribution of this application is the ability to perform precise and e cient angular measurements, ensuring more accurate and reliable diagnoses, benefiting both specialists and patients in the orthopedic field.en_US
dc.language.isospaen_US
dc.publisherUniversidad de las Ciencias Informáticas. Facultad de Tecnologías Interactivas (FTI).en_US
dc.subjectORTOPEDIAen_US
dc.subjectMETODO COBBen_US
dc.subjectDIAGNÓSTICOen_US
dc.subjectPARÁMETROSen_US
dc.subject.otherORTOPEDIAen_US
dc.subject.otherDESARROLLO DE SOFTWAREen_US
dc.subject.otherLENGUAJE DE PROGRAMACIÓNen_US
dc.subject.otherMETODOLOGÍAen_US
dc.subject.otherINTERFAZ GRÁFICAen_US
dc.subject.otherGESTIÓN DE INFORMACIÓNen_US
dc.titleFuncionalidad para el módulo de Ortopedia en el sistema XAVIA PACSViewer.en_US
dc.typebachelorThesisen_US
dc.rights.holderUniversidad de las Ciencias Informáticasen_US
Aparece en las colecciones: Trabajos de Diploma

Ficheros en este ítem:
Fichero Tamaño Formato  
TD_FTI_029_2024.pdf
  Restricted Access
4.32 MBAdobe PDFVisualizar/Abrir


Los ítems del Repositorio están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.